N/A
Standard: £10 + VATMembers/Subscribers: Free
Members/Subscribers, log in to access
The Structural Engineer, Volume 57, Issue 1, 1979
A requirement to check the widths of load-induced cracks is now a feature of current British Codes for structural concrete. However, the theoretical background to the procedures given in the Codes has not been published in a readily available and reasonably condensed form. This paper attempts to rectify this situation by presenting the derivation of a theory for the prediction of cracking in hardened concrete. This theory is shown to be a logical development of earlier theories, and is based on the extensive research program carried out at the Cement and Concrete Association over the last 14 years. The theory forms the basis of many Code crack prediction equations, and the derivation of these is discussed. A.W. Beeby
To be invited to give this Lecture is a great honour. Look at the list of my predecessors-alarmingly distinguished. Sir Anthony Part
Mr. T. A. G. Raikes (M) (Ove Arup Resident Engineer): We thought it would be useful to start the discussion by saying something of how the diaphragm wall construction worked out in practice, particularly in relation to the use of T-shaped and Ushaped panels.