Fire resistant design of concrete filled tubular steel columns

Author: Wang, Y C;Orton, A H

Date published

N/A

Price

Standard: £10 + VAT
Members/Subscribers: Free

Back to Previous

Fire resistant design of concrete filled tubular steel columns

Tag
Author
Wang, Y C;Orton, A H
Date published
N/A
Price

Standard: £10 + VAT
Members/Subscribers: Free

The Structural Engineer
Author

Wang, Y C;Orton, A H

Citation

The Structural Engineer, Volume 86, Issue 19, 2008

Date published

N/A

Author

Wang, Y C;Orton, A H

Citation

The Structural Engineer, Volume 86, Issue 19, 2008

Price

Standard: £10 + VAT
Members/Subscribers: Free

Concrete filled tubular (CFT) columns have many attractive features and are being increasingly used in prestigious projects. A design software package (Firesoft) has recently been developed to help make this type of construction more accessible to structural engineers. It is important the design software is thoroughly validated and this paper presents background information to the method adopted in the package. This method is based on the well established cold design method in EN 1994-1-1 for composite columns including CFT columns, but modified to take into account strength and stiffness degradations of steel and concrete at high temperatures. Although this method is not adopted in the fire part of Eurocode 4 (EN 1994-1-2) for composite columns including CFT columns, it has the advantage of using the same method for both cold and fire resistant designs of CFT columns. This paper first presents validation results for the alternative method by comparing Firesoft calculation results against the results of a large number of fire resistance tests on unprotected and externally protected CFT columns under axial compression or combined axial compression and bending moments. A study was then conducted to assess a current design method for externally protected CFT columns. The objective of the study is to propose an interim design method for externally protected
CFT columns that use intumescent coating until such time as reliable thermal properties of intumescent coating for CFT applications are available.



Y. C. Wang, BEng, PhD, CEng, FIStructE University of Manchester



A. H. Orton, BA, MICE, MIStructE Corus Tubes

Additional information

Format:
PDF
Publisher:
The Institution of Structural Engineers

Tags

Issue 19

Related Resources & Events

The Structural Engineer
<h4>Verulam</h4>

Verulam

Price – £10
The Structural Engineer
<h4>The structural engineer as artist</h4>
The Structural Engineer
<h4>Reinforced concrete structures in fire: a review of current rules</h4>

Reinforced concrete structures in fire: a review of current rules

This review of current design rules for fire resistance of reinforced concrete structures examines many of the assumptions on which these rules are based and presents evidence suggesting that the rules may be inadequate both for the assessment of the effects of spalling and the prevention of collapse. Initially it reviews the consequences of spalling on the performance of key concrete elements within a structure before describing effects which occur in complete structures that are not apparent from standard fire tests. This includes a review of fire incidents in real buildings, a compartment fire test carried out on the concrete frame at BRE Cardington, and a comparison with numerical models of concrete in fire. Results are also presented from a recent furnace test on a restrained post-tensioned slab. It concludes with a call for a fundamental review of the basis of the current rules and programme of testing of modern structural components. Fergal Kelly , BEng, PhD, CEng, MIStructE, Peter Brett Associates, London John Purkiss , BSc(Eng), PhD, CEng, MIStructE, MICE formerly Aston University

Author – Kelly, Fergal;Purkiss, John
Price – £10